Sign in →

Test Code LAB1234521 Herpes Simplex Virus (HSV), Molecular Detection, PCR, Spinal Fluid

Important Note

Mayo code is HSVC

Useful For

Aiding in the rapid diagnosis of herpes simplex virus (HSV)-1 and HSV-2 infections of the central nervous system

Reporting Name

Herpes Simplex Virus, PCR, CSF

Specimen Type

CSF


Specimen Required


Supplies: Sarstedt Aliquot Tube, 5 mL (T914)

Container/Tube: Plastic vial

Specimen Volume: 0.2 mL

Collection Instructions:

1. Submit from second spinal fluid collection vial.

2. Transfer into aliquot vial using sterile technique.

3. Do not centrifuge or heat inactivate.

Additional Information:

1. The high sensitivity of amplification by polymerase chain reaction (PCR) requires the specimen to be processed in an environment in which contamination of the specimen by herpes simplex virus DNA is not likely.

2. Specimens that are received with less than the minimum volume required for all testing requested will be canceled.


Specimen Minimum Volume

0.1 mL

Specimen Stability Information

Specimen Type Temperature Time Special Container
CSF Refrigerated (preferred) 7 days
  Frozen  7 days

Reject Due To

Heat-treated spinal fluid Reject

Reference Values

Negative

Supportive Data

Accuracy:

To assess the accuracy of the Diasorin Simplexa HSV (herpes simplex virus)-1 and -2 Direct assay, clinical spinal fluid (CSF) specimens (n=100) were tested and the results compared to those of the Roche HSV-1/2 analyte specific reagents.(6) Samples showing discordant results were tested by a third method (artus HSV-1/2; Qiagen). The results are summarized below in Tables 1 and 2:

 

Table 1. Comparison of the Simplexa HSV-1 Direct Assay to the Roche ASR using Clinical CSF Samples (n=100)(a).

Simplexa HSV-1

 

Roche HSV-1 ASR (b)

Positive

Negative

Positive

11

0

Negative

0

85

Total

11

85

 

Sensitivity (95% CI): 100% (70-100)

Specificity (95% CI): 100% (94.8-100)

 

Table 2. Comparison of the Simplexa HSV-2 Direct Assay to the Roche ASR using Clinical CSF Samples (n=100)(a).

Simplexa HSV-2

 

Roche HSV-2 ASR (b)

Positive

Negative

Positive

37

1

Negative

0

58

Total

37

59

 

Sensitivity (95% CI): 100% (88.8-100)

Specificity (95% CI): 98.3% (90.2-99.9)

 

(a) Only 96 samples are summarized. This is because 4 samples were found to be HSV detected-type indeterminate by the Roche ASR. These results are summarized in footnote b.

(b) One sample was HSV detected-type indeterminate by the Roche ASR and positive for HSV-1 by the Diasorin Simplexa assay. In addition, 3 samples were HSV detected-type indeterminate by the Roche ASR but negative by the Simplexa HSV-1 assay. These 3 samples were tested by a third method (artus HSV-1/2; Qiagen) and were negative for HSV-1 and -2. Testing was also repeated by the Roche ASR and the results were negative upon repeat testing.

Day(s) Performed

Monday through Sunday

Report Available

Same day/1 to 2 days

Specimen Retention Time

7 days

Performing Laboratory

Mayo Clinic Laboratories in Rochester

CPT Code Information

87529 x 2

87529 (if appropriate for government payers)

LOINC Code Information

Test ID Test Order Name Order LOINC Value
HSVC Herpes Simplex Virus, PCR, CSF 92865-5

 

Result ID Test Result Name Result LOINC Value
36858 HSV 1 PCR, C 16952-4
36859 HSV 2 PCR, C 16960-7

Testing Algorithm

For more information see Meningitis/Encephalitis Panel Algorithm.

Forms

If not ordering electronically, complete, print, and send a Microbiology Test Request (T244) with the specimen.