Test Code VLTS Volatile Screen, Serum
Performing Laboratory
Mayo Clinic Laboratories in RochesterReporting Name
Volatile Scrn, SSpecimen Type
SerumAdditional Testing Requirements
If measurement of ethylene glycol is also needed, order ETGL / Ethylene Glycol, Serum in addition to this test.
Specimen Required
Collection Container/Tube:
Preferred: Serum gel
Acceptable: Red top
Submission Container/Tube: Plastic vial for serum collected in red-top tubes only.
Specimen Volume: Full tube
Collection Instructions:
1. Do not use alcohol to clean arm. Use alternative such as Betadine to cleanse arm before collecting any specimen for volatile testing.
2. Avoid exposure of specimen to atmosphere.
3. Centrifuge serum gel tubes with 2 hours of collection but do not aliquot.
4. Centrifuge red-top tubes and aliquot serum in plastic vial within 2 hours of collection.
Reject Due To
Gross hemolysis | OK |
Gross lipemia | OK |
Gross icterus | OK |
Specimen Stability Information
Specimen Type | Temperature | Time | Special Container |
---|---|---|---|
Serum | Refrigerated (preferred) | 14 days | |
Frozen | 28 days | ||
Ambient | 24 hours |
Specimen Minimum Volume
0.5 mL
Day(s) Performed
Monday through Saturday
Specimen Retention Time
2 weeksReport Available
1 to 2 daysReference Values
Methanol:
Not detected (Positive results are quantitated.)
Toxic concentration: ≥10 mg/dL
Ethanol:
Not detected (Positive results are quantitated.)
Toxic concentration: ≥400 mg/dL
Isopropanol:
Not detected (Positive results are quantitated.)
Toxic concentration: ≥10 mg/dL
Acetone:
Not detected (Positive results are quantitated.)
Toxic concentration: ≥10 mg/dL
Useful For
Detection and quantitation of acetone, methanol, isopropanol, and ethanol in serum
Quantification of the concentration of ethanol in serum correlates with degree of intoxication
Evaluation of toxicity to the measured volatile substances
Testing Algorithm
This test includes analysis for methanol, ethanol, isopropanol, and acetone.
CPT Code Information
80320
G0480 (if appropriate)
LOINC Code Information
Test ID | Test Order Name | Order LOINC Value |
---|---|---|
VLTS | Volatile Scrn, S | 50025-6 |
Result ID | Test Result Name | Result LOINC Value |
---|---|---|
8632 | Volatile Scrn, S | 32044-0 |
30917 | Methanol, S | 5693-7 |
30918 | Ethanol, S | 5643-2 |
30919 | Acetone, S | 5568-1 |
30920 | Isopropanol, S | 5669-7 |
34376 | Chain of Custody | 77202-0 |
Forms
If not ordering electronically, complete, print, and send a Therapeutics Test Request (T831) with the specimen.