Test Code OLIGC Oligoclonal Banding, Spinal Fluid
Specimen Required
Only orderable as part of a profile. For more information, see:
-OLIG / Oligoclonal Banding, Serum and Spinal Fluid
-MSP3 / Multiple Sclerosis (MS) Profile, Serum and Spinal Fluid
Specimen Type: Spinal fluid
Container/Tube: Sterile vial
Specimen Volume: 0.5 mL
Collection Instructions: Label specimen as spinal fluid.
Useful For
Diagnosis of multiple sclerosis; especially useful in patients with equivocal clinical presentation and radiological findings
Reporting Name
CSF BandsSpecimen Type
CSFSpecimen Minimum Volume
See Specimen Required
Specimen Stability Information
Specimen Type | Temperature | Time | Special Container |
---|---|---|---|
CSF | Refrigerated (preferred) | 14 days | |
Ambient | 14 days | ||
Frozen | 14 days |
Reject Due To
All specimens will be evaluated at Mayo Clinic Laboratories for test suitability. |
Reference Values
Only orderable as part of a profile. For more information, see:
-OLIG / Oligoclonal Banding, Serum and Spinal Fluid
-MSP3 / Multiple Sclerosis (MS) Profile, Serum and Spinal Fluid
Cerebrospinal fluid Oligoclonal Bands Interpretation: <2 bands
Day(s) Performed
Monday through Friday
Report Available
4 to 7 daysSpecimen Retention Time
14 daysPerforming Laboratory
Mayo Clinic Laboratories in RochesterCPT Code Information
83916
LOINC Code Information
Test ID | Test Order Name | Order LOINC Value |
---|---|---|
OLIGC | CSF Bands | In Process |
Result ID | Test Result Name | Result LOINC Value |
---|---|---|
8017 | CSF Bands | 49852-7 |
23611 | CSF Olig Bands Interpretation | 100756-6 |