Sign in →

Test Code LAB770 Jo 1 Antibodies, IgG, Serum

Important Note

Mayo's test code: JO1

Performing Laboratory

Mayo Clinic Laboratories in Rochester

Reporting Name

Jo 1 Ab, IgG, S

Specimen Type

Serum


Specimen Required


Collection Container/Tube:

Preferred: Serum gel

Acceptable: Red top

Submission Container/Tube: Plastic vial

Specimen Volume: 0.5 mL

Collection Instructions: Centrifuge and aliquot serum into a plastic vial.


Reject Due To

Gross hemolysis Reject
Gross lipemia Reject
Gross icterus OK
Heat-Treated Reject

Specimen Stability Information

Specimen Type Temperature Time
Serum Refrigerated (preferred) 21 days
  Frozen  21 days

Specimen Minimum Volume

0.35 mL

Special Instructions

Day(s) Performed

Monday through Saturday

Specimen Retention Time

14 days

Report Available

1 to 3 days

Reference Values

<1.0 U (negative)

≥1.0 U (positive)

Reference values apply to all ages.

Useful For

Evaluating patients with clinical features of idiopathic inflammatory myositis, especially those with clinical features suggestive of anti-synthetase syndrome or interstitial lung disease

Testing Algorithm

For more information see Connective Tissue Disease Cascade.

CPT Code Information

86235

LOINC Code Information

Test ID Test Order Name Order LOINC Value
JO1 Jo 1 Ab, IgG, S 33571-1

 

Result ID Test Result Name Result LOINC Value
JO1 Jo 1 Ab, IgG, S 33571-1

Method Description

Recombinant Jo 1 antigen is coupled covalently to polystyrene microspheres, which are impregnated with fluorescent dyes to create a unique fluorescent signature. Jo 1 antibodies, if present in diluted serum, bind to the Jo 1 antigen on the microspheres. The microspheres are washed to remove extraneous serum proteins. Phycoerythrin (PE)-conjugated antihuman IgG antibody is then added to detect IgG anti-Jo 1 bound to the microspheres. The microspheres are washed to remove unbound conjugate, and bound conjugate is detected by laser photometry. A primary laser reveals the fluorescent signature of each microsphere to distinguish it from microspheres that are labeled with other antigens, and a secondary laser reveals the level of PE fluorescence associated with each microsphere. Results are calculated by comparing the median fluorescence response for Jo 1 microspheres to a 4-point calibration curve.(Package insert: Bioplex 2200 ANA Screen. Bio-Rad Laboratories, 02/2019)

Forms

If not ordering electronically, complete, print, and send a Kidney Transplant Test Request with the specimen.