Sign in →

Test Code LAB5341 Legionella pneumophila (Legionnaires Disease), Antibody, Serum

Important Note

Mayo's Test Code: SLEG

Performing Laboratory

Mayo Clinic Laboratories in Rochester

Reporting Name

Legionella Pneumophila Ab, S

Specimen Type

Serum


Specimen Required


Collection Container/Tube:

Preferred: Serum gel

Acceptable: Red top

Submission Container/Tube: Plastic vial

Specimen Volume: 0.5 mL

Collection Instructions: Centrifuge and aliquot serum into plastic vial.


Reject Due To

Gross hemolysis Reject
Gross lipemia Reject
Heat inactivated specimen Reject

Specimen Stability Information

Specimen Type Temperature Time Special Container
Serum Refrigerated (preferred) 14 days
  Frozen  14 days

Specimen Minimum Volume

0.4 mL

Day(s) Performed

Wednesday

Specimen Retention Time

14 days

Report Available

1 to 7 days

Reference Values

Negative

Reference values apply to all ages.

Useful For

Evaluating possible legionellosis (Legionnaires disease, Pontiac fever, extrapulmonary legionella infection caused by Legionella pneumophila)

CPT Code Information

86713

LOINC Code Information

Test ID Test Order Name Order LOINC Value
SLEG Legionella Pneumophila Ab, S 7947-5

 

Result ID Test Result Name Result LOINC Value
SLEG Legionella Pneumophila Ab, S 7947-5

Forms

If not ordering electronically, complete, print, and send Infectious Disease Serology Test Request (T916) with the specimen.