Test Code LAB5050 Complete Blood Count with Manual Differential
Useful For
Evaluation of anemia, leukemia, reaction to inflammation and infections, peripheral blood cellular characteristics, state of hydration and dehydration, polycythemia, hemolytic disease of the newborn and ABO incompatibilities. If the doctor requests a CBC with a manual diff, a manual differential or slide differential is done by a tech. All automated flagged differentials will automatically get a manual diff.
Performing Laboratory
Rogue Regional Medical Center /Three Rivers Medical Center / Ashland / Heimann and Spears Cancer Center Labs
Performing Department
Hematology
Specimen Required
Specimen Collection Container: Lavender top tube or Neonate Lavender Microtainer
Preferred volume 3.0 mL whole blood
Special Collection Instructions: Mix specimen gently by inversion 10 times.
Specimen Minimum Volume
1.0 ml whole blood
Neonatal minimum volume: 0.25 mL whole blood
Specimen Stability
Room temperature for up to 6 hours; otherwise, refrigerate at 2°–8°C for up to 24 hours.
Reject Due To
- Hemolysis
- Quantity not sufficient (QNS)
- Lacking Two Patient Identifiers:
- 1-Patient's First & Last name
- 2-Patient's Date of Birth
- Clotted specimen
Day(s) Performed
Performed: Daily
Turnaround Time from Receipt at Performing Laboratory:
- Routine/ASAP: ≤4 hours
- STAT: ≤60 minutes
Method Name
Automated Analyzer Cellular Analysis
Microscopic differential performed on a Wright stained peripheral blood smear.
CPT Code Information
85007 - Blood count; blood smear, microscopic examination with manual differential WBC count
85027 - Blood count; complete (CBC), automated (Hgb, Hct, RBC, WBC and platelet count)
Billing Code
2011898, 2011880