Sign in →

Test Code LAB468 Diazepam and Nordiazepam, Serum

Important Note

Mayo's test code: DIA

Test Down Notes

Effective December 14, 2023:  This test is temporarily unavailable due to analytic issues.  The downtime is expected to be >30 days.  Order ZW86 (1501SP) as an alternate.  See test notification here.

Performing Laboratory

Mayo Clinic Laboratories in Rochester

Reporting Name

Diazepam and Nordiazepam, S

Specimen Type

Serum Red


Specimen Required


Collection Container/Tube: Red top (Serum gel/SST are not acceptable)

Submission Container/Tube: Plastic vial

Specimen Volume: 0.5 mL

Collection Instructions: Centrifuge and aliquot serum into plastic vial.


Reject Due To

Gross hemolysis OK
Gross lipemia OK
Gross icterus OK

Specimen Stability Information

Specimen Type Temperature Time
Serum Red Refrigerated (preferred) 14 days
  Ambient  14 days
  Frozen  14 days

Specimen Minimum Volume

0.3 mL

Day(s) Performed

Monday, Wednesday

Specimen Retention Time

14 days

Report Available

3 to 7 days

Reference Values

Therapeutic concentrations

Diazepam and Nordiazepam: 200-2,500 ng/mL

Useful For

Assessing compliance

 

Monitoring for appropriate therapeutic level

 

Assessing diazepam toxicity

CPT Code Information

80299

LOINC Code Information

Test ID Test Order Name Order LOINC Value
DIA Diazepam and Nordiazepam, S 49044-1

 

Result ID Test Result Name Result LOINC Value
8629 Diazepam 3548-5
2475 Nordiazepam 3537-8
2459 Diazepam and Nordiazepam 16757-7

Forms

If not ordering electronically, complete, print, and send a Therapeutics Test Request (T831) with the specimen.