Test Code LAB155 CA125
Performing Laboratory
Asante Rogue Regional Medical Center (ARRMC)
Performing Department
Chemistry
Specimen Required
Specimen Minimum Volume
1.0 mL
Specimen Stability Information
Centrifuge collection tube and refrigerate within 2 hours of collection
Centrifuged SST is stable up to 7 das at 2° to 8° C. Aliquot and freeze serum if testing to be further delayed
Reject Due To
Hemolysis
Quantity not sufficient (QNS)
Lack of Two Patient Identifiers:
1-Patient’s First & Last name
2-Patient’s Date of Birth
Specimen stability time exceeded
Day(s) Performed
Monday through Sunday
Method Name
Chemiluminescence (CLIA) Testing performed on Beckman Coulter DXI600
CPT Code Information
86304
Billing Code
3020040
Cautions
Results from other manufactures or methodologies may vary in concentrations due to differences in reagent specificity and should not be used interchangeably. When performing serial samples over time, it is recommended that the same method be used, unless “re-baselined” with another method.