Test Code LAB1235500 ALLERGENS, FOOD PROFILE
Performing Laboratory
Asante Rogue Regional Medical Center (ARRMC)
Performing Department
Special Chemistry RRMC
Specimen Required
Yellow (Gold) top tube (SST) Tube must be full (to the fill line marked on the tube)
If using a short tube (3.5ml), or if you are ordering multiple panels please draw 2 full tubes.
Specimen Minimum Volume
2.5 mL
Specimen Stability Information
Centrifuge and refrigerate within 2 hours of collection
Spun SST is stable for 7 days if refrigerated at 2° to 8° C
Reject Due To
Lacking Two Patient Identifiers:
1-Patient's First & Last name
2-Patient's Date of Birth
QNS – Quantity Not Sufficient
Day(s) Performed
Tests batched on Tuesday and Friday
With results being approximately available after 4pm on the day of testing
Method Name
ImmunoCAP Fluorescent Enzyme Immunoassay
CPT Code Information
CPT 86003 x15, 82785 x1
This panel includes the following:
ALLERGEN, FOOD, EGG WHITE IGE
ALLERGEN, FOOD, MILK (COW) IGE
ALLERGEN, FOOD, PEANUT IGE
ALLERGEN, FOOD, SOYBEAN IGE
ALLERGEN, FOOD, SESAME SEED IGE
ALLERGEN, FOOD, WHEAT IGE
ALLERGEN, FOOD, HAZELNUT IGE
ALLERGEN, FOOD, WALNUT (JUGLANS SPP) IGE
ALLERGEN, FOOD, CASHEW IGE
ALLERGEN, FOOD, ALMOND IGE
ALLERGEN, FOOD, SCALLOP IGE
ALLERGEN, FOOD, SHRIMP IGE
ALLERGEN, FOOD, CODFISH IGE
ALLERGEN, FOOD, SALMON IGE
ALLERGEN, FOOD, TUNA IGE
IMMUNOGLOBULIN IGE
Billing Code
3000616 x15
30182785
Reference Values
Reference Interval |
Class |
Allergen Interpretation |
Less than 0.10 kU/L |
0 |
No significant level detected |
0.10-0.34 kU/L |
0/1 |
Clinical relevance undetermined |
0.35-0.70 kU/L |
1 |
Low |
0.71-3.50 kU/L |
2 |
Moderate |
3.51-17.50 kU/L |
3 |
High |
17.51-50.00 kU/L |
4 |
Very High |
50.01-100.00 kU/L |
5 |
Very High |
Greater than 100.00 kU/L |
6 |
Very High |
Testing is not useful in patients previously treated with immunotherapy to determine if residual clinical sensitivity exists. False-positive results may occur in patients with markedly elevated serum IgE (>2500 kU/L) due to nonspecific binding to allergen solid phases. Allergen results of 0.10-0.34 kU/L are intended for specialist use as the clinical relevance is undetermined.
IgE levels may not correlate with clinical response or physiologic response on specific allergen challenge. The correlation of allergen laboratory results with clinical history and in vivo reactivity to specific allergens is essential. A negative test may not rule out clinical allergy or even anaphylaxis.