Test Code LAB1234732 Anti-Mitochondrial M2 Ab (RDL)
Performing Laboratory
LabCorp
Specimen Required
Red Top Tube or gel-barrier tube
Volume: 1 mL
Minimum Volume: 0.3 mL (Note: This volume does not allow for repeat testing.)
Separate serum from cells within one hour of collection. Transfer to a plastic transport tube before shipping. To avoid delays in turnaround time when requesting multiple tests on frozen samples, please submit separate frozen specimens for each test requested.
Specimen Stability Information
Transport: Refrigerate or Freeze
Stability
Temperature |
Period |
---|---|
Room temperature |
7 days |
Refrigerated |
14 days |
Frozen |
60 days |
Freeze/thaw cycles |
Stable x1 |
Day(s) Performed
Report Available
7 - 14 days
Method Name
Enzyme-linked immunosorbent assay (ELISA)
CPT Code Information
86381
LOINC Code Information
Order Code | Order Code Name | Order Loinc | Result Code | Result Code Name | UofM | Result LOINC |
---|---|---|---|---|---|---|
520117 | Anti-Mitochondrial M2 Ab (RDL) | 8077-0 | 520118 | Anti-Mitochondrial M2 Ab (RDL) | Units | 8077-0 |