Test Code LAB1234728 Estradiol (Adult Males, Children, Postmenopausal Females, or Individuals on Estrogen-Suppressing Hormone Therapy)
Performing Laboratory
ARUP Laboratories
Specimen Required
Lithium Heparin Green Top Tube
Separate serum or plasma from cells within 2 hours after collection. Transfer 0.5 mL serum or plasma to an ARUP Standard Transport Tube. (Min 0.3 mL) Indicate age and sex of patient on test request form AND specimen tube.
Specimen Stability Information
Transport: Refrigerated
Stability after separation from cells: Ambient: 48 hours; Refrigerated: 1 week; Frozen: 1 month
Day(s) Performed
Performed: Sun-Sat
Reported: 1-4 days
Method Name
Quantitative High Performance Liquid Chromatography-Tandem Mass Spectrometry
CPT Code Information
82670
Interpretation
For a complete set of all established reference intervals, refer to ltd.aruplab.com/Tests/Pub/0093247.
This test was developed and its performance characteristics determined by ARUP Laboratories. It has not been cleared or approved by the US Food and Drug Administration. This test was performed in a CLIA certified laboratory and is intended for clinical purposes.
LOINC Code Information
Component Test Code* | Component Chart Name | LOINC |
---|---|---|
0093247 | Estradiol by Mass Spec | 35384-7 |
* Component test codes cannot be used to order tests. The information provided here is not sufficient for interface builds