Sign in →

Test Code LAB1234725 Matrix Metalloproteinase-9 (MMP-9)

Important Note

ARUP's Test Code: 3005003

Performing Laboratory

ARUP Laboratories

Specimen Required

Yellow (Gold) top tube (SST)

 

Transfer 1 mL serum to an ARUP Standard Transport Tube and freeze immediately. (Min: 0.5 mL)
Test is not performed at ARUP; separate specimens must be submitted when multiple tests are ordered.

Specimen Stability Information

Transport: CRITICAL FROZEN

 

Stability: Ambient: Unacceptable; Refrigerated: Unacceptable; Frozen: 2 months

Day(s) Performed

Performed: Varies

 

Reported: 3-10 days

Method Name

Quantitative Enzyme-Linked Immunosorbent Assay

CPT Code Information

83520

LOINC Code Information

Component Test Code* Component Chart Name LOINC
3005004 Matrix Metalloproteinase-9 (MMP-9) 60243-3

* Component test codes cannot be used to order tests. The information provided here is not sufficient for interface builds