Test Code LAB1234673 Troponin I High Sensitivity with Reflex
Performing Laboratory
- Asante Rogue Regional Medical Center (ARRMC)
- Asante Three Rivers Medical Center (ATRMC)
- Asante Ashland Community Hospital (AACH)
Performing Department
Chemistry
Specimen Required
Lithium Heparin Green top tube
Short samples that only produce plasma close to the gel interface after centrifugation will not be accepted.
Ensure there is no residual fibrin or cellular matter in the plasma after centrifugation.
Specimen Stability Information
Centrifuged plasma is stable at room temperature for up to 4 hours.
Samples are stable for up to 48 hours refrigerated at 2⁰-8⁰C.
Frozen specimens are stable for up to 180 days at -20⁰C or colder. Frozen specimens should be thawed only once at room temperature and re-centrifuged prior to testing.
Reject Due To
- Quantity not sufficient (QNS)
- Lack of Two Patient Identifiers:
- 1-Patient’s First & Last name
- 2-Patient’s Date of Birth
Day(s) Performed
Testing performed 7 days a week on all shifts.
- ASAP - 2 hours after receipt of specimen in lab.
- STAT – 1 hour after receipt of specimen in lab.
Method Name
Chemiluminescent immunoassay
CPT Code Information
CPT 84484
Billing Code
3010199
Additional Tests
This testing includes a reflex that will automatically generate a new Troponin I High Sensitivity test to be completed two hours after the initial testing was drawn.