Test Code LAB1234606 Prothrombin (F2) c.*97G>A (G20210A) Pathogenic Variant
Useful For
Order to detect prothrombin c.*97G>A (G20210A) pathogenic variant.
Performing Laboratory
ARUP Laboratories
Specimen Required
Transport 3 mL whole blood. (Min: 1 mL)
Specimen Stability Information
Transport: Refrigerated only.
Stability: Ambient: 72 hours; Refrigerated: 1 week; Frozen: 1 month
Reject Due To
- Plasma or serum
- collection of specimen in sodium heparin tubes
- Frozen specimens in glass collection tubes.
Day(s) Performed
Sun-Sat
Method Name
Polymerase Chain Reaction/Fluorescence Monitoring
CPT Code Information
81240
Interpretation
Background Information for Prothrombin (F2) c.*97G>A (G20210A) Pathogenic Variant:
Characteristics: The Factor II, c.*97G>A (G20210A) pathogenic variant is a common genetic risk factor for venous thrombosis associated with elevated prothrombin levels leading to increased rates of thrombin generation and excessive growth of fibrin clots. The expression of Factor II thrombophilia is impacted by coexisting genetic thrombophilic disorders, acquired thrombophilic disorders (eg, malignancy, hyperhomocysteinemia, high factor VIII levels), and circumstances including: pregnancy, oral contraceptive use, hormone replacement therapy, selective estrogen receptor modulators, travel, central venous catheters, surgery, and organ transplantation.
Incidence: Approximately 2 percent of Caucasians and 0.3 percent of African Americans are heterozygous; homozygosity occurs in 1 in 10,000 individuals.
Inheritance: Incomplete autosomal dominant.
Penetrance: The risk of thrombosis is increased 2-4 fold for heterozygotes and further increased for homozygotes.
Cause: Homozygosity or heterozygosity for F2 c.*97G>A (G20210A).
Pathogenic Variant Tested: F2 c.*97G>A (G20210A).
Clinical Sensitivity for Venous Thrombosis: Approximately 10 percent.
Methodology: Polymerase chain reaction and fluorescence monitoring.
Analytical Sensitivity and Specificity: 99 percent.
Limitations: Diagnostic errors can occur due to rare sequence variations. F2 gene variants, other than c.*97G>A (G20210A), will not be detected.
This test was developed and its performance characteristics determined by ARUP Laboratories. It has not been cleared or approved by the US Food and Drug Administration. This test was performed in a CLIA certified laboratory and is intended for clinical purposes.
Counseling and informed consent are recommended for genetic testing. Consent forms are available online.
LOINC Code Information
Component Test Code* | Component Chart Name | LOINC |
---|---|---|
0056060 | Prothrombin (F2) G20210A Variant | 24475-6 |
2001334 | PT PCR Specimen | 31208-2 |
* Component test codes cannot be used to order tests. The information provided here is not sufficient for interface builds.
Secondary ID
- F2 DNA assay
- Factor II (PT) 20210 Variant