Test Code HEAG Hepatitis B Virus e Antigen and Hepatitis B Virus e Antibody, Serum
Performing Laboratory
Mayo Clinic Laboratories in Rochester
Reporting Name
Hepatitis Be Ag and Ab, SSpecimen Type
Serum SSTOrdering Guidance
If ordered with HBVQN / Hepatitis B Virus (HBV) DNA Detection and Quantification by Real-Time PCR, Serum; send separate vials.
Necessary Information
Date of collection is required
Specimen Required
Patient Preparation: For 24 hours before specimen collection, patient should not take multivitamins or dietary supplements (eg, hair, skin, and nail supplements) containing biotin (vitamin B7).
Supplies: Sarstedt Aliquot Tube, 5 mL (T914)
Collection Container/Tube: Serum gel (red-top tubes are not acceptable)
Submission Container/Tube: Plastic vial
Specimen Volume: 0.8 mL Serum
Collection Instructions:
1. Centrifuge blood collection tube per manufacturer's instructions (eg, centrifuge and aliquot within 2 hours of collection for BD Vacutainer tubes).
2. Aliquot serum into a plastic vial.
Reject Due To
| Gross hemolysis | Reject |
| Gross lipemia | Reject |
| Gross icterus | Reject |
Specimen Stability Information
| Specimen Type | Temperature | Time |
|---|---|---|
| Serum SST | Frozen (preferred) | 90 days |
| Refrigerated | 6 days | |
| Ambient | 72 hours |
Specimen Minimum Volume
Serum: 0.7 mL
Special Instructions
Day(s) Performed
Monday through Saturday
Specimen Retention Time
14 daysReport Available
Same day/1 to 3 daysReference Values
HEPATITIS B e ANTIGEN:
Negative
HEPATITIS B e ANTIBODY:
Negative
For more information see Viral Hepatitis Serologic Profiles.
Useful For
Determining the presence or absence of detectable hepatitis B virus e antigen and antibody in monitoring infection status of individuals with chronic hepatitis B
Determining infectivity of hepatitis B virus (HBV) carriers
Monitoring serologic response of chronically HBV-infected patients receiving antiviral therapy
CPT Code Information
86707
87350
LOINC Code Information
| Test ID | Test Order Name | Order LOINC Value |
|---|---|---|
| HEAG | Hepatitis Be Ag and Ab, S | 77176-6 |
| Result ID | Test Result Name | Result LOINC Value |
|---|---|---|
| EAG | Hepatitis Be Ag, S | 13954-3 |
| HEAB | HBe Antibody, S | 33463-1 |
Method Description
Hepatitis B Virus e Antigen:
The Elecsys HBeAg (hepatitis B e antigen) assay is based on the sandwich principle and performed using an electrochemiluminescence immunoassay on the automated cobas e 801 immunochemistry analyzer. HBeAg present in patient's sample reacts with 2 biotinylated monoclonal anti-HBeAg antibodies and a mixture of monoclonal anti-HBeAg antibody and polyclonal anti-HBeAg antibodies labeled with a ruthenium complex react to form a sandwich complex. After addition of streptavidin-coated microparticles (solid phase), the complexes bind to this solid phase via interaction of biotin and streptavidin. The reaction mixture is aspirated into the measuring cell where the microparticles are magnetically captured onto the surface of the electrode. Unbound substances are then washed away, and voltage is applied to the electrode that induces chemiluminescent emissions, which are measured by a photomultiplier. The test result is determined by comparing the electrochemiluminescence signal generated from the patient's sample to the cutoff index (COI) value set from reagent lot-specific assay calibration.(Package insert: Elecsys HBeAg. Roche Diagnostics, v1.0, 10/2020)
Hepatitis B Virus e Antibody:
The Elecsys Anti-HBe (hepatitis B virus e antibody) assay is based on the competitive immunoassay principle and performed using an electrochemiluminescence method on the automated cobas e 801 immunochemistry analyzer. Anti-HBe present in the patient's sample first binds to the added synthetic HBeAg. The remaining unbound sites on the synthetic HBeAg become occupied with the added biotinylated antibodies and ruthenium complex-labeled antibodies specific for HBeAg. The entire complex becomes bound to the streptavidin-coated microparticles (solid phase) via interaction of biotin and streptavidin. The reaction mixture is then aspirated into the measuring cell where the microparticles are magnetically captured onto the surface of the electrode. Unbound substances are then washed away, and voltage is applied to the electrode that induces chemiluminescent emissions, which are measured by a photomultiplier. Test result is determined by comparing the electrochemiluminescence signal generated from the sample to the COI value set from reagent lot-specific assay calibration.(Elecsys Anti-HBe. Roche Diagnostics; v1.0, 12/2021)
Profile Information
| Test ID | Reporting Name | Available Separately | Always Performed |
|---|---|---|---|
| EAG | Hepatitis Be Ag, S | Yes | Yes |
| HEAB | HBe Antibody, S | Yes | Yes |
Forms
If not ordering electronically, complete, print, and send 1 of the following: