Test Code CRYPS Cryptosporidium Antigen, Feces
Performing Laboratory
Mayo Clinic Laboratories in RochesterReporting Name
Cryptosporidium Ag, FSpecimen Type
FecalSpecimen Required
Submit only 1 of the following specimens:
Specimen Type: Preserved feces
Supplies:
-Formalin 10% Buffered Neutral 15 mL (T466)
-Stool Collection Kit, Random (T635)
Container/Tube:
Preferred: Stool container with 10% buffered formalin preservative
Acceptable: SAF (sodium acetate formalin)
Specimen Volume: 5 grams
Specimen Stability Information: Ambient (preferred) 60 days
Specimen Type: Unpreserved feces
Supplies:
-Stool container, Small (Random), 4 oz (T288)
-Stool Collection Kit, Random (T635)
Container/Tube: Stool container
Specimen Volume: 5 grams
Specimen Stability Information: Frozen 60 days
Reject Due To
Grossly bloody (containing no visible feces) Very mucoid feces Specimen preserved in ECOFIX (green cap), C and S (orange cap), or methiolate formalin (MF) Duodenal aspirates Small bowel aspirates |
Reject |
Specimen Stability Information
Specimen Type | Temperature | Time | Special Container |
---|---|---|---|
Fecal | Varies |
Specimen Minimum Volume
1 gram
Special Instructions
Day(s) Performed
Monday through Friday
Specimen Retention Time
Fresh/Frozen: 1 week; Preserved specimens: 1 weekReport Available
1 to 3 daysReference Values
Negative
Useful For
Establishing the diagnosis of intestinal cryptosporidiosis
Testing Algorithm
For other diagnostic tests that may be of value in evaluating patients with diarrhea; the following algorithms are available:
CPT Code Information
87328
LOINC Code Information
Test ID | Test Order Name | Order LOINC Value |
---|---|---|
CRYPS | Cryptosporidium Ag, F | 6371-9 |
Result ID | Test Result Name | Result LOINC Value |
---|---|---|
24086 | Cryptosporidium Ag, F | 6371-9 |
Forms
If not ordering electronically, complete, print, and send 1 of the following forms with the specimen:
-Gastroenterology and Hepatology Test Request (T728)
-Microbiology Test Request (T244)
Supportive Data
The sensitivity, specificity, positive predictive value and negative predictive value of the enzyme-linked immunosorbent assay were 98%, 98%, 98%, and 98.5%, respectively, as determined by examination of 130 fecal specimens by conventional microscopy and by enzyme-linked immunosorbent assay.